Language

For the detection of IgM Antibody to Hepatitis B Core Antigen in human (HBcAb test kit CLIA)

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-12 19:23

  • Browse the number:

    195

Send an inquiries
Company Profile
Nantong Egens Biotechnology Co. Ltd
By certification [File Integrity]
Contact:

egens-bio(Mr.)  

Telephone:

Area:

Beijing

Address:

Block A No.15 Building, No.1692,Xinghu Avenue, Development District, Nantong, Jiangsu, China (226010)

Website:

http://egens-bio.jhtattoo168.com/

Categories

Product Details
Model Number: HBcAb IgM CLIA01 Brand Name: Egens Key Specifications/Special Features: ThisHBcAbIgMCLIAisaqualitativemicroplatechemiluminescenceassayfortheinvitrodetectionofIgMantibodytoHepatitisBCoreAntigeninhumanserumorplasma.Thisassayhastheadvantageofbeingsensitive,specific,simple,andfast.IthasgreatsignificanceinthediagnosisofHBVinfection.Assay procedure:1. Dilute samples: Use the Normal Saline(0.9% NaCl) to dilute the samples(The samples must bediluted 1:999 before use.). The Positive Control and Negative Control have no use for dilution.2. Add Samples and Conjugate: Open the foil pouch and remove the Microplate. Set up 1 well as Blank, 2 wells as standard,1 well as negative control, 1 well as positive control. After dispensing 50μL of standard or Negative Control or Positive Control t or samples to the respective wells, add 50μl of Conjugate into each well except the blank. Gently vibrating the plate.3. Incubate: Cover the Microplate with Plate Cover and incubate the Microplate in a thermostat-controlled water-bath or microplate incubator at 37℃ for 30 minutes.4. Wash: Wash the Microplate for 5 times. Fill the wells with above 350μL of the diluted Washing Buffer, Soak for above 30 seconds, then aspirate again for each time. Make sure that the rest volume is minimal by tapping plate at absorbent paper.5. Add Substrate: Add 50μL of Substrate Solution A and 50μL of Substrate Solution B to each well, Vibrate the Microplate. Cover and incubate the Microplate in the dark at room temperature (18-24℃) for 5-10 minutes.6. Read the RLU value by a microplate chemiluminescence immunoassay analyzer.
Shipping Information:
  • FOB Port: Shanghai
  • Lead Time: 15 - 30 days
Main Export Markets:
  • Asia
  • Australasia
  • Central/South America
  • Eastern Europe
  • Mid East/Africa
  • North America
  • Western Europe